TB20-C, Bus Coupler PROFINET IO
The PROFINET bus coupler is designed to connect a PROFINET bus to TB20 peripheral modules.
A functioning TB20 configuration will always require a bus coupler and at least one peripheral module, but can accommodate up to 63 modules of any kind connected in series with the bus coupler. The bus coupler supports hot-plug for replacing modules during operation.
In addition, it will recognize all connected peripheral modules and assign each module the corresponding inputs/outputs from the process image table.
PROFINET bus coupler with Power over Ethernet (PoE):
A PROFINET bus coupler version featuring Power over Ethernet (PoE) will soon be available as well.
This bus coupler will make it possible to run a distributed I/O station with nothing more than an Ethernet cable.
Characteristics
• I/O device as per PROFINET IO (61158-6-10)
• Integrated two-port switch
• Full-duplex transmission rate of 100 Mbps
• 340 bytes of I/O data
• Up to 63 peripheral modules
• Modules can be replaced during operation (hot-plug)
• Conformance Class C
• Media Redundancy Protocol (MRP)
• Automatic addressing / hot-swapping (LLDP, DCP)
• Topology discovery
• I&M data
• Diagnostic alarms, process alarms, pull/plug alarms
• Integration using GSDML file
• 24 VDC power supply
• Integrated power supply unit for powering peripheral modules (2.5 A)
• Supplies the system’s I/O voltage (24 VDC)
• 7 LEDs, two of them bi-color
• USB device port for online diagnostics, configuring parameters, setup, and firmware updates with "TB20 ToolBox"
• TB20 ToolBox simulation for setting up the I/O system without a higher-level controller in order to test the system`s
operation (I/O check)
• Concealed "factory reset" switch for restoring the module to its factory settings
TB20-C, Bus Coupler EtherNet/IP
The EtherNet/IP bus coupler makes it possible to access data from peripheral modules using the EtherNet/IP protocol.
A functioning TB20 configuration will always require a bus coupler and at least one peripheral module, but can accommodate up to 64 modules of any kind connected in series with the bus coupler. The bus coupler supports hot-plug for replacing modules during operation.
It detects peripheral modules that are plugged in and allows access to the modules` I/O data via input/output assemblies.
The EtherNet/IP bus coupler features an integrated two-port switch that allows for star and line topology configurations.
A large I/O image table size of one kbyte makes it possible to implement comprehensive and complex systems.
TB20 ToolBox can be used to easily configure the system and the various module parameters and transfer the corresponding settings to the coupler.
Characteristics
• Supports unicast and multicast CIP connections
• 511 bytes of input assembly data; 511 bytes of output assembly data
• TB20 ToolBox can be used for easy access to assembly sizes and to the structure of the image table within the
assemblies
• Up to 64 peripheral modules
• Modules can be replaced during operation (hot-plug)
• Implicit messaging (transport class 1)
• Explicit messaging (transport class 3)
• TCP watchdog
• IP address can be set relative to a base IP address by using a DIP switch that can be covered
• DHCP (can be selected using DIP switch)
• Integrated two-port switch with two RJ45 connectors
• Module process data is automatically assigned to the EtherNet/IP mapping
• 24 VDC power supply
• Integrated power supply unit for powering peripheral modules (2.5 A)
• Supplies the system’s I/O voltage (24 VDC)
• 9 LEDs, three of them bi-color
• USB device port for online diagnostics, configuring parameters, setup, and firmware updates with "TB20 ToolBox"
• TB20 ToolBox simulation for setting up the I/O system without a higher-level controller in order to test the system`s
operation (I/O check)
TB20-C, Bus Coupler Profibus-DP
The PROFIBUS DP bus coupler is designed to connect a PROFIBUS bus to TB20 peripheral modules. It supports the DP-V0 and DP-V1 protocols.
A functioning TB20 configuration will always require a bus coupler and at least one peripheral module, but can accommodate up to 64 modules of any kind connected in series with the bus coupler. The bus coupler supports hot-plug for replacing modules during operation.
In addition, it will recognize all connected peripheral modules and assign each module the corresponding inputs/outputs from the process image table.
Characteristics
• PROFIBUS DP slave as defined in EN 50170/IEC 61158
• Supports all PROFIBUS baud rates
• DP-V0 and DP-V1 support
• Up to 64 peripheral modules
• Modules can be replaced during operation (hot-plug)
• Up to 244 bytes of input data and 244 bytes of output data
• One class 1 master connection with 240 bytes of payload data
• Up to three class 2 master connections with 240 bytes of payload data (as a DP-V1 slave)
• Bit packing for 2-bit and 4-bit modules
• 24 VDC power supply
• I&M data
• Integrated power supply unit for powering peripheral modules (2.5 A)
• Supplies the system’s I/O voltage (24 VDC)
• DIP switch for setting the PROFIBUS address; can be covered
• 3 LEDs, two of them bi-color
• USB device port for online diagnostics, configuring parameters, setup, and firmware updates with "TB20 ToolBox"
• TB20 ToolBox simulation for setting up the I/O system without a higher-level controller in order to test the system`s
operation (I/O check)
PART NUMBER | DESCRIPTION |
600-180-1AA11 | Bus Coupler PROFINET IO, comes with 24 V power supply connector, final bus cover, base module |
600-175-1AA11 | Bus Coupler EtherNet/IP, comes with 24 V power supply connector, final bus cover, base module |
600-151-1AA11 | Bus Coupler PROFIBUS-DP Slave, comes with 24 V power supply connector, final bus cover, base module |
Remote IO Stations for S7-300/S7-400 Controllers
Remote IO Stations for CompactLogix System/ Controllogix System